SmartDrop™ XF Nano Espectrofotômetro + Fluorômetro Accuris
SmartDrop Nano Espectrofotômetros para Análise de Microvolume de DNA, RNA e Proteínas.
DESCRIÇÃO
SmartDrop Nano Espectrofotômetros para Análise de Microvolume de DNA, RNA e Proteínas.
Resultados rápidos e precisos de uma gota de amostra.
Painel de controle com tela sensível ao toque, sem necessidade de PC ou software.
Impressora integrada e porta de cubeta para leituras OD600.
O modelo XF inclui fluorômetro para DNA sensível quantificação.
Especificações técnicas:
Model SmartDrop L (NS1000) SmartDrop X (NS1010) SmartDrop XF (NS1020)
Display 7-inch touch screen 7-inch touch screen 7-inch touch screen
Minimum sample size 1.0µl – 2.0µl 0.5µl – 2.0µl 0.5µl – 2.0µl
Path length 0.5mm 0.2mm, 1.0mm 0.05mm, 0.2mm, 1.0mm
Light source UV LED Xenon Flash Lamp Xenon Flash Lamp
Detector UV Silicon Photocell 2048 Element Linear Silicon CCD Array 2048 Element Linear Silicon CCD Array
Wavelength 260, 280, & 600nm 200 – 800nm (1nm steps) 200 – 800nm (1nm steps)
Absorbance range 0.2 – 50 A (10mm equivalent) 0.04 – 90 A (10mm equivalent) 0.04 – 300 A (10mm equivalent)
Absorbance precision 0.005 A 0.003 A 0.003 A
Lower limit of detection dsDNA: 10ng/µl; BSA: 0.1 mg/ml dsDNA: 2ng/µl; BSA: 0.1mg/ml dsDNA: 2ng/µl ; BSA: 0.1mg/ml
Upper limit of detection dsDNA: 2,500ng/µl; BSA: 75.0 mg/ml dsDNA: 4,500ng/µl; BSA: 135mg/ml dsDNA: 15,000ng/µl; BSA: 360mg/ml
Detection time < 6 seconds < 5 seconds < 6 seconds
Communication ports USB for data export USB for data export USB for data export
Voltage input DC 24V, 2A DC 24V, 2A DC 24V, 2A
Power 25W 25W 25W
Dimensions (WxDxH) 20.8 x 8.0 x 18.6 cm / 8.2 x 11.0 x 7.3 in. 20.8 x 8.0 x 18.6 cm / 8.2 x 11.0 x 7.3 in. 20.8 x 8.0 x 18.6 cm / 8.2 x 11.0 x 7.3 in.
Weight 3.6 kg / 7.9 lbs 2.8 kg / 6.2 lbs 3.6 kg / 7.9 lbs
Cuvette OD600 detection
Absorbance range 0.0 – 4.0 A 0.0 – 4.0 A 0.0 – 4.0 A
Absorbance stability [0,3) ≤ 0.5%, [3,4) ≤ 2% [0,3) ≤ 0.5%, [3,4) ≤ 2% [0,3) ≤ 0.5%, [3,4) ≤ 2%
Absorbance repeatibility [0,3) ≤ 0.5%, [3,4) ≤ 2% [0,3) ≤ 0.5%, [3,4) ≤ 2% [0,3) ≤ 0.5%, [3,4) ≤ 2%
Absorbance precision [0,2) ≤ 0.005 A, [2,3) ≤ 1%, [3,4) ≤ 2% [0,2) ≤ 0.005 A, [2,3) ≤ 1%, [3,4) ≤ 2% [0,2) ≤ 0.005 A, [2,3) ≤ 1%, [3,4) ≤ 2%
Fluorescence detection
Excitation/Emission N/A N/A 460 ± 20nm / 525-570nm
Sensitivity N/A N/A dsDNA: 0.5pg/µl
Linearity N/A N/A R² ≥ 0.995
Repeatability N/A N/A ≤ 1.5%
Stability N/A N/A ≤ 1.5%